Blog

MT49S advanced G3-PLC communication

MT49S: Advanced G3-PLC Communication for Better Connectivity

ModemTec is proud to introduce the MT49S PLC Communication Modem, a highly advanced and robust device designed to deliver superior performance and reliability in power line communication. As industries evolve towards smarter, more connected operations, the MT49S stands out by offering cutting-edge features that leverage G3-PLC technology, making it the ideal solution for utilities, energy management, and […]

Partial discharge measurement chain in comprehensive diagnostic system

How to create comprehensive Partial Discharge Diagnostic System

Creating a comprehensive partial discharge diagnostic system is essential for monitoring and assessing the condition of electrical insulation in high-voltage equipment. This article explores how to develop such system, highlighting key concepts, components, and methodologies. Introduction The degradation of insulation state in high-voltage systems can be caused by various factors, including partial discharges (PD). Partial discharges are […]

Enlit Europe 2024 in Milan

Join us at Enlit Europe 2024 in Milan!

ModemTec is excited to announce our participation in the Enlit Europe 2024 Exhibition in Milan! This is a fantastic opportunity to connect with experts and innovators from the energy sector, and we’re thrilled to showcase our latest developments and advanced diagnostic solutions. 📅 Date: 22-24 October 2024📍 Location: Fiera Milano, Italy🤝 Czech Pavilion, Stand: 7.D60 […]

Vessel partial discharge monitoring

Vessel Partial Discharge Monitoring for Enhanced Maritime Safety

The PD Doctor is an advanced Partial Discharge (PD) online monitoring system designed to maintain the integrity of electrical networks aboard marine vessels. Installed on the main distribution board bus bar, the PD Doctor continuously monitors partial discharge activity on each of the three phases of the vessel’s electrical system. This system helps identify potential […]

Bathtub curve of product life cycle

Difference between offline and online partial discharge monitoring

In the field of electrical equipment diagnostics, the ultimate goal is not only to detect existing issues but to accurately predict the future reliability and performance of the equipment. This is especially critical when monitoring partial discharges, which can indicate potential insulation failures in high-voltage systems. While both offline and online partial discharge monitoring methods […]

Case 1 - Line degradation and replacement

Results and Operational Experience of Partial Discharge Monitoring

Dozens of PD Doctor installations across Europe have proven their high added user value and reliability for customers. They have detected degradation of existing lines, helped eliminate high interference on overhead lines, established the link between rainy weather and increasing partial discharge (PD) activity, for example, or helped save significant amounts of money by postponing […]

PD Doctor Analyzer

PD Doctor: Improving Reliability and reducing Costs of Smart Grids

As society’s dependence on electricity increases, the issue of the quality of power supply and the elimination of unexpected outages comes to the fore. This is made possible primarily by diagnostics and its tools. The rapid development of diagnostics goes hand in hand with the increasing complexity of diagnostic systems and new technical possibilities in […]

International Conference on Diagnostics in Electrical Engineering – Diagnostika24

International Conference on Diagnostics in Electrical Engineering

🌟 ModemTec is proud to be a Gold Sponsor at the upcoming 2024 International Conference on Diagnostics in Electrical Engineering (Diagnostika24), hosted by the University of West Bohemia in Pilsen. We will showcase our cutting-edge Partial Discharge Online Monitoring System – PD Doctor, which plays a crucial role in enhancing the safety and reliability of […]

PLC Communication diagnostics basics

PLC Communication Diagnostics Basics

Power Line Carrier (PLC) communication uses the low-voltage distribution network. It is completely irrelevant what standard or proprietary protocol is used. Meter reading systems use the same frequency band and distribution system, which always has similar characteristics and behavior. What influences the effectivity of PLC communication? Among the influences that affect data transmission from e-meters […]

PRPD diagram of PD monitoring at transformer station in Poland

Partial Discharge Monitoring at Transformer Station in Poland

We were tasked to provide continous online partial discharge monitoring system, to enhance the safety and reliability of a vital energy distribution point in Poland. Site inspection led us to deploy the PD Doctor system within a 15 kV transformer station, and subsequent to a successful installation, a period of stable discharge activity was observed. […]