Low Voltage Line PLC Modems

Low Voltage Line
PLC Modems

PLC Modems designed for use at existing Low Voltage lines up to 1 000 V. They provide data channel with excellent noise immunity and long communication distance (up to 5 km) without the need for repeaters.

Modem MT49S / MT49R / MT34R

PLC modem for use in Power Line Carrier Communication over Low Voltage Lines. Provided PLC Communication is stable, reliable, and operates successfully also in disturbed environment.

MT49S PLC modem
PLC modem MT34R

Key features:

  • Operates on any power lines 0 to 1,000 V
  • Extraordinary communication distance up to 5 000 m
  • Communication interfaces RS485, RS232 or RS422*
  • Single-phase and three-phase variants
  • Advanced DSP algorithms and error-correction codes
  • Routing in the network
  • High transmission output, narrowband communication
  • Easy configuration through RSet application

*Valid for MT34R modem

Typical applications:

  • Communication in the industry and transport
    • Production processes, energy balance
    • Connection with remote sites (boreholes, treatment plants, Photovoltaics …)
    • Maritime transport automation systems
  • Smart grids
    • Meter readings (electricity, water, heat, gas …)
    • Distribution control
  • Building automation
    • Industrial areas, office and residential buildings
    • Museums, archives, historic buildings, halls and stadiums

Modem Comparison

MT49S Modem is designed to provide a data connection via existing 230 V power lines. The advantage of the modem is automatic and adaptive build of G3-PLC network according to the parameters of LV line and creation of an encrypted tunnel for transparent data transfers. It allows to use any protocol (Modbus, DLMS, Profibus, etc.) using standard interfaces such as RS485, RS232 or Ethernet.

Modem MT49R is an intelligent interface between PLC communication line and connected device with serial line (i.e. PC, programmable logic controller, intelligent e-meter etc.). Module receives data from connected device via serial line and subsequently trasmits received data to the PLC communication channel. You can transfer data in any protocol to a maximum length of one packet of 60 Kbyte.

MT34R Modem is designed to realize a data connection over an existing 230/400 V power lines. It has RS485, RS422 or RS232 serial interface, which can transfer almost any protocol, thanks to the transparent mode. The device can be operated not only in pair mode for interconnected two points, but it is also possible to create larger networks containing repeaters.

MT-49SMT-49RMT-34R
Number of phases for Rx/Tx113
PLC standardG3-PLCMTECMTEC
Max. communication rate280 kbps10 kbps10 kbps
InterfacesRS232, RS485, EthernetRS232, RS485RS232, RS485, RS422
Carrier frequency adjustment
Possibility of external coupling
Binary state transfer
Automatic routing
Advanced encryptionAES-128

Technical Specifications

PLC communication

Carrier frequency154 – 487 kHz (MT49S)
60 – 145 kHz (MT49R)
40 – 120 kHz (MT34R)
ModulationDBPSK, DQPSK*, D8PSK*
PLC standardG3-PLC (MT49S)
MTEC (MT49R, MT34R)
Output amplitude134 dB/µV (MT49S/R)
128 dB/µV (MT34R)
(RL = 12 Ω)
Output currentMax. 1 APP (MT49S/R)
Max. 2 APP (MT34R)
Input sensitivity1 mV
Amplitude adjustmentYes, manual
Minimal SNR> 3 dB (PER 10-4) (MT49S)
> 9 dB (PER 10-4) (MT49R/34R)
ProtectionOver-current, short-circuit, thermal
PLC couplerBuilt-in internal
Output to an external couplerOn request
*Valid for MT49S modem

Power supply

Voltage85 – 305 VAC (MT49S/R)
100 – 430 VDC (MT49S/R)
3×230/230 V ±10 % (MT34R)
Frequency47 – 440 Hz (MT49S/R)
50 Hz ± 3 % (MT34R)
Power consumptionMax. 15 W (MT49S/R)
Max. 40 W (MT34R)

Dimensions and weight

W x H x D106 x 90 x 57 mm (MT49S/R)
250 x 235 x 150 mm (MT34R)
Weight450 g (MT49S/R)
1500 g (MT34R)

Data interface

Main dataRS485, RS232, RS422*
Galvanic isolationYes
ProtocolTransparent mode
Baudrate300 – 230400 bps
Data bits7, 8
ParityNone, odd, even
Stop bits1, 2
Data buffer8 kB (MT49S)
64 kB (MT49R/34R)
*Valid for MT34R modem

Environment

Operating temperature-40 to +60 °C
Storage temperature-40 to +70 °C
Relative humidity*0 – 95 %
*No water condensation

Safety

Electrical appliance class II – double insulated
Comply withEN 61010, EN 60529, EN 61000, EN 60870, EN 50065

Mounting

MountingDIN 35 rail mounting (MT49S/R)
BP CombiCard 6000 (MT34R)
EnclosurePlastic
IP ratingIP30 (MT49S/R)
IP65 (MT34R)

MT49S Modem Variants

The MT49S modem comes in 8 different variants, based on the capabilities supported. These variants are explained by the following table:

VariantG3-PLCRS232, RS485LANExternal PLC Coupler4x binary I/O
MT49S
MT49S-G
MT49S-B
MT49S-C
MT49S-GB
MT49S-GC
MT49S-BC
MT49S-GBC

MT49S

MT49S PLC modem data sheet

MT49R

MT-49R PLC modem data sheet

MT34R

MT-34R PLC modem data sheet
ModemTec
Information regarding the use of cookies on our website

What are cookies files?

Cookies are files that are stored in your device during your browsing on our website. Cookies are used to remember certain information about the user mainly in order to improve consumer interface, communication between the website and your device and simplify and accelerate functions of our website. Besides technical cookies that are essential for operation of the website, we use cookies to help us to inform you in case of maintenance of the website – those cookies obtain the information regarding the display of the alert information – and to analyse your preference and activity on the website by Google Analytics (“GA”) for the purpose of improving the provided services. With help of Google Analytics, we gain information of your activities on the website, your IP address and information of the type of your device (the “Personal Data”).

Cookies’ settings

Cookies preferences are set via a pop-up bar that appears the first time you visit our website. As a default setting, disagreement with analytical cookies is set up. Analytical and advertising cookies will be processed only in case of your agreement expressed by ticking the appropriate box on the bar. Technical cookies are allowed. Technical cookies cannot be switched off, because they are essential for proper operation of the website. The settings can always be changed by clicking to the link "cookies settings". The link is located on the bottom bar.

Your rights

Please note that you have a right to:

  • revoke your consent to the processing of Personal Data by changing the cookies settings according to the steps above,
  • require information on what Personal Data our company processes
  • require explanation regarding the processing of your Personal Data and demand correction provided the Personal Data are processed incorrectly (e.g. blocking, amendment, completion of liquidation of the Personal Data),
  • demand access to the Personal Data and their amendment of the data,
  • demand deletion of the Personal Data or to limit their processing if they are processed unlawfully,
  • right to lodge a complaint against the processing of the Personal Data,
  • right to transfer the Personal Data, i.e. right to gain overview of the data we process and transfer them to another administrator,
  • in case of doubts of compliance with the obligations regarding processing of the personal data to inform us or the Data Protection Office on (https://www.uoou.cz/), with which you can lodge a complaint.

If you have any queries regarding cookies or this information sheet or if you want to use your above-stated rights, do not hesitate to contact us on [email protected].